DC Contactor Kiepe GN
The Kiepe GN series DC contactors are electromagnetic switches in accordance with VDE 0660, Part 1/3.68. They have proven themselves successful for decades in their current design.
The requirements for trackless electric battery vehicles in accordance with DIN 43 553/1.73 have been largely taken into consideration. The insulation requirements of the contactor, the clearance and creepage distance are met in accordance with DIN EN 50 124-1:2001. The Kiepe GN series electromagnetic DC contactors are
made in a 1-pole and/or 2-pole design. They are used for the switching
of DC motors and in DC onboard power systems - e.g. as a battery
contactor. The contactors are switched on with DC solenoids and
the resetting is carried out by spring tension. The solenoids are
available for 3 operation ranges.
As an auxiliary switch, up to 2 ausiliary switch blocks
can be attached. Every auxiliary switch block das 1 normally open
contact and 1 normally closed contact. The auxiliary switches are
equipped with a 6.3 mm fast-on connector. The main contact - with double interruption - is
designed for rated voltages up to DC 600 V. A permanent magnetic blower
device is integrated for extinguishing the electric arc when being
switched off. The correct polarity should therefore be acertained
during connection. The switching capacity was checked corresponding to
VDE 0660/Part 102 with the switching categories DC 1, DC 2/3 and DC 4/5. If the contacts are parallelly switched with the2-pole
contactor, the rated thermal current is reduced to the values given in
the technical data for parallel switching. The main contacts are
equipped with a M10 screw terminal. The contactor is constructed on a steel base plate,
which at the same time serves as the mounting. During the planning of
the installation, the required minimum distances and the possible
assembly positions are to be observed. The contactors are meant for installation in rooms
where no difficult operating conditions occur due to effects of dust,
moisture or atmospheric influences.
Range 1 (+10/-30 %) is especially suitable for battery-powered
systems, range 2 (+10/-15 %) for industrial DC power systems and range
3 (+20/-30 %) for train applications. For protection from transient
voltage spikes during the switching off of the solenoids, these can be
equipped with a varistor as voltage surge protection. The drive magnets
are equipped with a 6.3 mm fast-on connector.
Download:
Gleichstromschuetz_GN_566_E.pdf
(Größe: 400.0 KB)