Current Relay Kiepe STV
Function of the current relay is to break the control voltage to the electromagnetic coil of a contactor, via an auxiliary switch when the current exceeds a predetermined set value.
Function with Locking Device
Function without Locking Device
The current relay consists of 6 sub assemblies. These are: Constructional Unit
Hinged Armature
Trip Coil
Interlocking withTrip Coil
Switching Elements
Setting of Switching Points
Function
When set trip value is exceeded, the hinged armature moves, operates the switching elements and is mechanically locked.
lf the actual current value drops below the set trip condition, the
?locked? switching element can be unlocked by briefly energizing the
coil of the unlocking device.
The hinged armature remains in the down position as long
as the preset value is exceeded. lf the value drops, the armature moves
back into the starting position. The set value has to be indicated when
ordering.Construction
Constructional Unit consists of base plate of insulating
material, magnet yoke with supporting plate for switching elements,
interlock with interlocking coil and stop for stroke limitation of
hinged armature.
Hinged armature consists of armature screwed to an
insulatingbase plate and a set screw for switching element and set
screw for stroke limitation.
The current coil operating the magnet system consists of a
core with copper-wire-windings. Current coil from type No. 36 on has
rectangular copper-wire windings.
Interlock/release consists of operating coil and magnet system whose flexible armature interlock the hinged armature.
Switching elements consist of auxiliary switches and their supports.
Setting of release values is possible by means of pressure
spring, guide bar, indication plate and self-locking setting nut. The
position and value is calibrated by Kiepe at the factory and is sealed
with red lacquer.